362
14 CFR Ch. I (1–1–24 Edition)
§ 25.1449
(4) Portable oxygen equipment must
be immediately available for each
cabin attendant. The portable oxygen
equipment must have the oxygen dis-
pensing unit connected to the portable
oxygen supply.
(5) When operating into or out of air-
ports with elevations above 13,000 feet,
the dispensing units providing the re-
quired oxygen flow must be automati-
cally presented to the occupants at
cabin pressure altitudes no higher than
2,000 feet above the airplane’s max-
imum takeoff and landing altitude.
[Doc. No. 5066, 29 FR 18291, Dec. 24, 1964, as
amended by Amdt. 25–41, 42 FR 36971, July 18,
1977; Amdt. 25–87, 61 FR 28696, June 5, 1996;
Amdt. 25–116, 69 FR 62789, Oct. 27, 2004; Amdt.
No. 25–151, 88 FR 39161, June 15, 2023; 88 FR
44032, July 11, 2023]
§ 25.1449
Means for determining use of
oxygen.
There must be a means to allow the
crew to determine whether oxygen is
being delivered to the dispensing equip-
ment.
§ 25.1450
Chemical oxygen generators.
(a) For the purpose of this section, a
chemical oxygen generator is defined
as a device which produces oxygen by
chemical reaction.
(b) Each chemical oxygen generator
must be designed and installed in ac-
cordance with the following require-
ments:
(1) Surface temperature developed by
the generator during operation may
not create a hazard to the airplane or
to its occupants.
(2) Means must be provided to relieve
any internal pressure that may be haz-
ardous.
(3) Except as provided in SFAR 109,
each chemical oxygen generator instal-
lation must meet the requirements of
§ 25.795(d).
(c) In addition to meeting the re-
quirements in paragraph (b) of this sec-
tion, each portable chemical oxygen
generator that is capable of sustained
operation by successive replacement of
a generator element must be placarded
to show—
(1) The rate of oxygen flow, in liters
per minute;
(2) The duration of oxygen flow, in
minutes, for the replaceable generator
element; and
(3) A warning that the replaceable
generator element may be hot, unless
the element construction is such that
the surface temperature cannot exceed
100 degrees F.
[Amdt. 25–41, 42 FR 36971, July 18, 1977, as
amended at 79 FR 13519, Mar. 11, 2014]
§ 25.1453
Protection of oxygen equip-
ment from rupture.
Oxygen pressure tanks, and lines be-
tween tanks and the shutoff means,
must be—
(a) Protected from unsafe tempera-
tures; and
(b) Located where the probability and
hazards of rupture in a crash landing
are minimized.
§ 25.1455
Draining of fluids subject to
freezing.
If fluids subject to freezing may be
drained overboard in flight or during
ground operation, the drains must be
designed and located to prevent the
formation of hazardous quantities of
ice on the airplane as a result of the
drainage.
[Amdt. 25–23, 35 FR 5680, Apr. 8, 1970]
§ 25.1457
Cockpit voice recorders.
(a) Each cockpit voice recorder re-
quired by the operating rules of this
chapter must be approved and must be
installed so that it will record the fol-
lowing:
(1) Voice communications trans-
mitted from or received in the airplane
by radio.
(2) Voice communications of flight
crewmembers on the flight deck.
(3) Voice communications of flight
crewmembers on the flight deck, using
the airplane’s interphone system.
(4) Voice or audio signals identifying
navigation or approach aids introduced
into a headset or speaker.
(5) Voice communications of flight
crewmembers using the passenger loud-
speaker system, if there is such a sys-
tem and if the fourth channel is avail-
able in accordance with the require-
ments of paragraph (c)(4)(ii) of this sec-
tion.
VerDate Sep<11>2014
09:06 Jun 28, 2024
Jkt 262046
PO 00000
Frm 00372
Fmt 8010
Sfmt 8010
Y:\SGML\262046.XXX
262046
jspears on DSK121TN23PROD with CFR