[PDF]
| Casting factor | Inspection |
|---|---|
| 2.0 or greater | 100 percent visual. |
| Less than 2.0, greater than 1.5 | 100 percent visual, and magnetic particle (ferromagnetic materials), penetrant (nonferromagnetic materials), or approved equivalent inspection methods. |
| 1.25 through 1.50 | 100 percent visual, and magnetic particle (ferromagnetic materials). penetrant (nonferromagnetic materials), and radiographic or approved equivalent inspection methods. |
| Dihedral angle (light included) | Angle from right or left of longitudinal axis, measured from dead ahead | Intensity (candles) |
|---|---|---|
| L and R (forward red and green) | 10° to 10° 10° to 20° 20° to 110° | 40 30 5 |
| A (rear white) | 110° to 180° | 20 |
| Angle above or below the horizontal plane | Intensity, l |
|---|---|
| 0° | 1.00 |
| 0° to 5° | 0.90 |
| 5° to 10° | 0.80 |
| 10° to 15° | 0.70 |
| 15° to 20° | 0.50 |
| 20° to 30° | 0.30 |
| 30° to 40° | 0.10 |
| 40° to 90° | 0.05 |
| Overlaps | Maximum Intensity | |
|---|---|---|
| Area A (candles) | Area B (candles) | |
| Green in dihedral angle L | 10 | 1 |
| Red in dihedral angle R | 10 | 1 |
| Green in dihedral angle A | 5 | 1 |
| Red in dihedral angle A | 5 | 1 |
| Rear white in dihedral angle L | 5 | 1 |
| Rear white in dihedral angle R | 5 | 1 |
| Angle above or below the horizontal plane | Effective intensity (candles) |
|---|---|
| 0° to 5° | 150 |
| 5° to 10° | 90 |
| 10° to 20° | 30 |
| 20° to 30° | 15 |
| Frequency | Field strength (volts/meter) | |
|---|---|---|
| Peak | Average | |
| 10 kHz-2 MHz | 50 | 50 |
| 2 MHz-30 MHz | 100 | 100 |
| 30 MHz-100 MHz | 50 | 50 |
| 100 MHz-400 MHz | 100 | 100 |
| 400 MHz-700 MHz | 700 | 50 |
| 700 MHz-1 GHz | 700 | 100 |
| 1 GHz-2 GHz | 2,000 | 200 |
| 2 GHz-6 GHz | 3,000 | 200 |
| 6 GHz-8 GHz | 1,000 | 200 |
| 8 GHz-12 GHz | 3,000 | 300 |
| 12 GHz-18 GHz | 2,000 | 200 |
| 18 GHz-40 GHz | 600 | 200 |
| In this table, the higher field strength applies at the frequency band edges. | ||
| Frequency | Field strength (volts/meter) | |
|---|---|---|
| Peak | Average | |
| 10 kHz-500 kHz | 20 | 20 |
| 500 kHz-2 MHz | 30 | 30 |
| 2 MHz-30 MHz | 100 | 100 |
| 30 MHz-100 MHz | 10 | 10 |
| 100 MHz-200 MHz | 30 | 10 |
| 200 MHz-400 MHz | 10 | 10 |
| 400 MHz-1 GHz | 700 | 40 |
| 1 GHz-2 GHz | 1,300 | 160 |
| 2 GHz-4 GHz | 3,000 | 120 |
| 4 GHz-6 GHz | 3,000 | 160 |
| 6 GHz-8 GHz | 400 | 170 |
| 8 GHz-12 GHz | 1,230 | 230 |
| 12 GHz-18 GHz | 730 | 190 |
| 18 GHz-40 GHz | 600 | 150 |
| In this table, the higher field strength applies at the frequency band edges. | ||
| Frequency | Field strength (volts/meter) | |
|---|---|---|
| Peak | Average | |
| 10 kHz-100 kHz | 150 | 150 |
| 100 kHz-400 MHz | 200 | 200 |
| 400 MHz-700 MHz | 730 | 200 |
| 700 MHz-1 GHz | 1,400 | 240 |
| 1 GHz-2 GHz | 5,000 | 250 |
| 2 GHz-4 GHz | 6,000 | 490 |
| 4 GHz-6 GHz | 7,200 | 400 |
| 6 GHz-8 GHz | 1,100 | 170 |
| 8 GHz-12 GHz | 5,000 | 330 |
| 12 GHz-18 GHz | 2,000 | 330 |
| 18 GHz-40 GHz | 1,000 | 420 |
| In this table, the higher field strength applies at the frequency band edges. | ||